Endress+Hauser
| Measuring Principle: Coriolis | Application: Liquids and gases needing low pressure loss and gentle fluid treatment, with in-line viscosity measurement |
| Size Range: DN 8 to 80 (⅜" to 3") | Brand: Endress+Hauser |
File Download
| MEASURING PRINCIPLE |
| Principle: Coriolis mass flow measurement with straight single-tube design, independent of fluid properties such as viscosity or density |
| APPLICATION |
| Liquids and gases in applications requiring low pressure loss and gentle fluid treatment |
| In-line viscosity measurement in addition to mass flow, density and temperature |
| SIZE RANGE / CONNECTIONS |
| Nominal diameter: DN 8 to 80 (⅜" to 3") |
| PROCESS CONDITIONS |
| Medium temperature: –50 to +150 °C (–58 to +302 °F) |
| Max. process pressure: PN 100 / Class 600 / 63K |
| WETTED MATERIALS |
| Measuring tube: Titanium grade 9 |
| Connection: Titanium grade 2 |
| KEY FEATURES |
| Sensor design: straight, easy-to-clean single-tube system with TMB technology |
| Pressure loss: full-bore design for minimal pressure loss |
| Mass flow accuracy (liquid): ±0.10 % |
| Mass flow accuracy (gas): ±0.50 % |
| Density accuracy (liquid): ±0.0005 g/cm³ |
| Measuring range: 0 to 180,000 kg/h (0 to 6,600 lb/min) |
| Multivariable measurement: flow, density, temperature and viscosity |
| Compact transmitter: dual-compartment housing with up to 3 I/Os, remote display available |
| Display: backlit, touch control, WLAN access |
| Installation: no inlet or outlet run needed |
| Heartbeat Technology: integrated verification |
| Brand / Product Family |
| Brand: Endress+Hauser |
| Product family: Proline Promass |