EH-PROMASS-Q300

Proline Promass Q 300 Coriolis Flowmeter

Endress+Hauser


    Measuring Principle: Coriolis Application: Highest-accuracy mass flow, volume flow and density; custody transfer and liquids with entrained gas
    Size Range: DN 25 to 250 (1" to 10") Brand: Endress+Hauser


    MEASURING PRINCIPLE
    Principle: Coriolis mass flow measurement, independent of fluid properties such as viscosity or density
    APPLICATION
    Highest measurement accuracy for mass flow, volume flow and density
    Preferred choice for custody transfer applications
    Optimized for liquid applications where entrained gas is present
    SIZE RANGE / CONNECTIONS
    Nominal diameter: DN 25 to 250 (1" to 10")
    PROCESS CONDITIONS
    Medium temperature (standard): –50 to +205 °C (–58 to +401 °F)
    Medium temperature (cryogenic option): –196 to +150 °C (–321 to +302 °F)
    Max. process pressure: PN 100 / Class 600 / 63K
    WETTED MATERIALS
    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)
    KEY FEATURES
    Mass flow accuracy (liquid): ±0.10 % (standard), ±0.05 % (option, PremiumCal)
    Mass flow accuracy (gas): ±0.25 %
    Density accuracy (liquid): ±0.0002 g/cm³ (standard), ±0.0001 g/cm³ (option)
    Measuring range: 0 to 2,400,000 kg/h (0 to 88,183 lb/min)
    Entrained gas handling: MFT (Multi-Frequency Technology)
    Turndown: high turndown due to low pressure loss and zero point
    Multivariable measurement: flow, density and temperature
    Compact transmitter: dual-compartment housing with up to 3 I/Os, remote display available
    Display: backlit, touch control, WLAN access
    Installation: no inlet or outlet run needed
    Heartbeat Technology: integrated verification