| Measuring Principle: Electromagnetic | Application: Water and wastewater: drinking water, utility water, industrial and municipal wastewater |
| Size Range: DN 25 to 3000 (1" to 120") | Brand: Endress+Hauser |
File Download
| MEASURING PRINCIPLE |
| Principle: Electromagnetic flow measurement, bidirectional, virtually independent of pressure, density, temperature and viscosity |
| APPLICATION |
| Versatile standard flowmeter for the water and wastewater industry |
| Ideal for water measurement, e.g. drinking water, utility water and industrial or municipal wastewater |
| SIZE RANGE / CONNECTIONS |
| Nominal diameter: DN 25 to 3000 (1" to 120") |
| Process connections: sensor with fixed or lap-joint process connections |
| PROCESS CONDITIONS |
| Medium temperature (hard rubber liner): 0 to +80 °C (+32 to +176 °F) |
| Medium temperature (polyurethane liner): –20 to +50 °C (–4 to +122 °F) |
| Medium temperature (PTFE liner): –20 to +90 °C (–4 to +194 °F) |
| Max. process pressure: PN 40 / Class 300 / 20K |
| WETTED MATERIALS |
| Liner: hard rubber; polyurethane; PTFE |
| Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum |
| KEY FEATURES |
| Volume flow accuracy: ±0.5 % o.r. ± 1 mm/s (standard), ±0.2 % o.r. ± 2 mm/s (option, Flat Spec) |
| Measuring range: 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1,665 Mgal/d) |
| Installation: 0 x DN inlet run with constant accuracy, no pressure loss |
| Versions: compact or remote |
| Underground and underwater use: corrosion protection for underground or underwater installation |
| Transmitter housing: durable polycarbonate or aluminium |
| Display: backlit, touch control (operation without opening the device), WLAN access |
| Operation: integrated web server, no additional software or hardware needed |
| Data logger: integrated, for monitoring measured values |
| Heartbeat Technology: integrated verification and build-up detection |
| Brand / Product Family |
| Brand: Endress+Hauser |
| Product family: Proline Promag |