EH-PMD63B

Deltabar PMD63B - Differential Pressure Transmitter

Endress+Hauser


    Measuring Principle : Differential pressure Application : Hydrostatic level and differential pressure of liquids and gases, including filter monitoring
    Measuring Range : 100 mbar to 40 bar (1.5 to 580 psi) Brand : Endress+Hauser


    MEASURING PRINCIPLE
    Principle : Differential pressure
    Accuracy : Up to 0.075%
    Long-Term Stability : 0.025% of URL per year
    APPLICATION
    Application : Hydrostatic level and differential pressure of liquids and gases, and filter monitoring
    MEASURING RANGE / CONNECTIONS
    Measuring Range : 100 mbar to 40 bar (1.5 to 580 psi)
    Smallest Calibratable Span : 5 mbar (0.07 psi), max. turndown 100:1
    Flanges : DN50 to DN80, NPS 1-1/2" to 3", DIN 11852
    Hygienic Connections : Tri-Clamp 1-1/2" to 3"
    PROCESS CONDITIONS
    Process Temperature : -40 to +250 °C (-40 to +482 °F)
    Max. Static Pressure : 240 bar (3,480 psi)
    Vacuum Resistance : 50 mbar (0.73 psi)
    WETTED MATERIALS
    Membrane : 316L stainless steel
    Gaskets : PTFE, FKM, EPDM, FFKM (options)
    KEY FEATURES
    Output : 4-20 mA HART, PROFIBUS PA, PROFINET over Ethernet-APL, Bluetooth
    Technology : TempC Membrane (temperature compensation), Heartbeat Technology, SmartBlue app
    Safety : SIL2/3, ATEX
    Brand : Endress+Hauser
    Product Family : Deltabar