EH-TMASS-F300
| Measuring Principle : Thermal Mass Flow (Inline) | Application : Utility and process gases, gas mixtures in small line sizes |
| Size Range : DN15-100 (½"-4") | Brand : Endress+Hauser |

EH-TMASS-I300
| Measuring Principle : Thermal Mass Flow (Insertion) | Application : Utility and process gases and gas mixtures in circular piping or rectangular ducts |
| Size Range : DN80-1500 (3"-60") | Brand : Endress+Hauser |

EH-TMASS-I500
| Measuring Principle : Thermal Mass Flow (Insertion) | Application : Utility and process gases and gas mixtures in circular piping or rectangular ducts |
| Size Range : DN80-1500 (3"-60") | Brand : Endress+Hauser |

EH-PROWIRL-F200
| Measuring Principle : Vortex | Application : Steam (including wet steam), gases and liquids |
| Size Range : DN15-300 (½"-12") | Brand : Endress+Hauser |

EH-PROSONIC-G500
| Measuring Principle : Ultrasonic (Gas) | Application : Natural and process gas in the chemical, oil and gas industries |
| Size Range : DN25-300 (1"-12") | Brand : Endress+Hauser |

EH-PROSONIC-G300
| Measuring Principle : Ultrasonic (Gas) | Application : Natural and process gas in the chemical, oil and gas industries |
| Size Range : DN25-300 (1"-12") | Brand : Endress+Hauser |

EH-PROSONIC-B200
| Measuring Principle : Ultrasonic (Gas) | Application : Wet biogas and digester gas |
| Size Range : DN50-200 (2"-8") | Brand : Endress+Hauser |

EH-PROMASS-F300
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases under varying, demanding process conditions |
| Size Range : DN8-250 (⅜"-10") | Brand : Endress+Hauser |

EH-PROMASS-A300
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases at lowest flow rates, all industries |
| Size Range : DN1-4 (1/24"-1/8") | Brand : Endress+Hauser |

EH-PROMASS-E300
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases in a wide range of standard applications |
| Size Range : DN8-80 (⅜"-3") | Brand : Endress+Hauser |

EH-PROMASS-E500
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases in a wide range of standard applications |
| Size Range : DN8-80 (⅜"-3") | Brand : Endress+Hauser |

EH-PROMASS-F500
| Measuring Principle: Coriolis | Application: Liquids and gases under varying, demanding process conditions |
| Size Range: DN 8 to 250 (⅜" to 10") | Brand: Endress+Hauser |

EH-PROMASS-I300
| Measuring Principle: Coriolis | Application: Liquids and gases needing low pressure loss and gentle fluid treatment, with in-line viscosity measurement |
| Size Range: DN 8 to 80 (⅜" to 3") | Brand: Endress+Hauser |

EH-PROMASS-K10
| Measuring Principle: Coriolis | Application: Basic mass flow tasks such as air, gas, fuel and water; utility processes |
| Size Range: DN 8 to 80 (⅜" to 3") | Brand: Endress+Hauser |

EH-PROMASS-Q300
| Measuring Principle: Coriolis | Application: Highest-accuracy mass flow, volume flow and density; custody transfer and liquids with entrained gas |
| Size Range: DN 25 to 250 (1" to 10") | Brand: Endress+Hauser |

EH-PROMASS-Q500
| Measuring Principle: Coriolis | Application: Highest-accuracy mass flow, volume flow and density; custody transfer and liquids with entrained gas |
| Size Range: DN 25 to 250 (1" to 10") | Brand: Endress+Hauser |

EH-PROMAG-P300
| Measuring Principle: Electromagnetic | Application: Chemical and process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |

EH-PROMAG-H100
| Measuring Principle: Electromagnetic | Application: Hygienic applications in the food and beverage and life sciences industries |
| Size Range: DN 2 to 150 (1/12" to 6") | Brand: Endress+Hauser |

EH-PROMAG-W400
| Measuring Principle: Electromagnetic | Application: Water and wastewater: drinking water, utility water, industrial and municipal wastewater |
| Size Range: DN 25 to 3000 (1" to 120") | Brand: Endress+Hauser |

EH-PROMAG-H300
| Measuring Principle: Electromagnetic | Application: Hygienic applications in the food and beverage and life sciences industries |
| Size Range: DN 2 to 150 (1/12" to 6") | Brand: Endress+Hauser |

EH-PROMAG-P200
| Measuring Principle: Electromagnetic | Application: Chemical and process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 200 (½" to 8") | Brand: Endress+Hauser |

EH-PROMAG-P500
| Measuring Principle: Electromagnetic | Application: Chemical and process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |

EH-PROMAG-P10
| Measuring Principle: Electromagnetic | Application: Basic process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |

EH-PROMAG-W10
| Measuring Principle: Electromagnetic | Application: Basic water and wastewater applications, such as raw water intake |
| Size Range: DN 25 to 3000 (1" to 120") | Brand: Endress+Hauser |

EH-PICOMAG
| Measuring Principle: Electromagnetic | Application: Conductive liquids in secondary circuits; process quality control and monitoring in utilities |
| Size Range: DN 15 to 50 (½" to 2") | Brand: Endress+Hauser |

EH-PROMAG-55S
| Measuring Principle: Electromagnetic | Application: Inhomogeneous, abrasive and corrosive fluids with high solids content |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |

EH-FMR20B
| Measuring Principle : Free-space Radar, 80 GHz | Application : Basic level measurement in basins, sewers, pump stations, tanks and silos |
| Measuring Range : Up to 30 m (98.4 ft) | Brand : Endress+Hauser |

EH-FMR43
| Measuring Principle : Free-space Radar, 80 GHz (180 GHz optional) | Application : Continuous non-contact level measurement in hygienic processes |
| Measuring Range : Up to 15 m (49 ft) | Brand : Endress+Hauser |

EH-FMR52
| Measuring Principle : Time-of-Flight Radar (K-band) | Application : Aggressive liquids, pastes and slurries; hygiene-sensitive food and life sciences |
| Measuring Range : Up to 40 m (131 ft) | Brand : Endress+Hauser |

EH-FMR60B
| Measuring Principle : Free-space Radar, 80 GHz | Application : Liquid applications with small process connections, vessels with many internal fittings |
| Measuring Range : Up to 50 m (164 ft) | Brand : Endress+Hauser |

EH-FMR62B
| Measuring Principle : Free-space Radar, 80 GHz | Application : Demanding liquid applications: high temperature, high pressure, variable media |
| Measuring Range : Up to 80 m (262 ft) | Brand : Endress+Hauser |

EH-FMR63B
| Measuring Principle : Free-space Radar, 80 GHz | Application : Continuous non-contact level measurement in hygienic applications |
| Measuring Range : Up to 80 m (262 ft) | Brand : Endress+Hauser |

EH-FTL43
| หลักการวัด |
| สวิตช์วัดระดับแบบ Vibronic ดีไซน์สุขอนามัยสำหรับของเหลว ใช้ส้อมสั่นตรวจจับว่าถูกสารปกคลุมหรือไม่ |
| การใช้งาน |
| ตรวจจับระดับแบบจุดในถังกระบวนการ ถังเก็บ และท่อ ในงานสุขอนามัย เช่น ตรวจจับระดับในสกิดและโมดูลที่แคบสำหรับของเหลวหลายชนิด ป้องกันปั๊มทำงานแห้งในท่อ และป้องกันล้นในถังกระบวนการ |
| ความยาวโพรบและการเชื่อมต่อ |
| ความยาวโพรบ : เซนเซอร์กะทัดรัด 148 มม. ถึง 1500 มม. (6.00" ถึง 59") |
| การเชื่อมต่อกระบวนการ (เกลียว) : G¾A, G1A |
| การเชื่อมต่อกระบวนการ (หน้าแปลน) : DN 25 ถึง DN 50 (EN 1092-1), NPS 2" Class 150 (ASME B16.5) |
| การเชื่อมต่อกระบวนการ (สุขอนามัย) : Tri-Clamp (DIN 11851), Ingold, Flush mount, DRD, SMS 1145, Varivent |
| ความหนาแน่นสารขั้นต่ำ : 0.5 g/cm³ (25.0 lb/ft³); ตัวเลือก 0.4 g/cm³ (31.2 lb/ft³) |
| สภาวะกระบวนการ |
| ช่วงอุณหภูมิ : -40°C ถึง +150°C (-40°F ถึง +302°F) |
| ช่วงความดัน : สุญญากาศ ถึง 64 bar (สุญญากาศ ถึง 928 psi) |
| วัสดุส่วนที่สัมผัสกับกระบวนการ |
| ส้อม / ข้อต่อกระบวนการ : 316L |
| ซีล (ตัวเลือก) : VMQ, EPDM |
| ตัวเรือนทรานสมิตเตอร์ : 316L ตัวเลือกขัดเงาด้วยไฟฟ้า (Electropolished) |
| คุณสมบัติเด่น |
| • ใช้งานแบบ Plug and play ตั้งค่าเริ่มต้นง่าย |
| • รักษาความถูกต้องของการตั้งค่าด้วย CRC Checksum |
| • วินิจฉัยต่อเนื่องด้วย Heartbeat Technology |
| • ดีไซน์สุขอนามัยที่ได้รับการรับรอง พร้อมการตรวจสอบย้อนกลับวัสดุ |
| ยี่ห้อ : Endress+Hauser |
| ตระกูลสินค้า : Liquiphant |

EH-FTL51B
| Measuring Principle : Vibronic (vibrating fork) | Application : Point level detection in all liquid media in the process industry |
| Probe Length : Up to 6 m (19.7 ft) with pipe extension | Brand : Endress+Hauser |

EH-FTL33
| Measuring Principle : Vibronic (vibrating fork) | Application : Overfill prevention and pump dry-run protection in compact hygienic applications |
| Probe Length : Compact | Brand : Endress+Hauser |

EH-FTL63
| Measuring Principle : Vibronic (vibrating fork) | Application : Point level detection in hygienic and aseptic processes, all pumpable liquids |
| Probe Length : Compact to 3 m (9.85 ft) | Brand : Endress+Hauser |

EH-FTM51
| Measuring Principle : Vibronic (vibrating fork) | Application : Point level switch for fine-grained solids and powders in silos |
| Probe Length : 300-4000 mm (12"-155") | Brand : Endress+Hauser |

EH-FMP51
| Measuring Principle : Guided Wave Radar (Time-of-Flight) | Application : Liquids, pastes and slurries under extreme process conditions, including interface measurement |
| Measuring Range : Up to 45 m (148 ft) | Brand : Endress+Hauser |

EH-FMP52
| Measuring Principle : Guided Wave Radar (Time-of-Flight) | Application : Liquids, pastes and slurries in aggressive media, including interface measurement |
| Measuring Range : Up to 45 m (148 ft) | Brand : Endress+Hauser |

EH-FDU91F
| Measuring Principle : Ultrasonic Time-of-Flight | Application : Non-contact level of liquids, pastes, sludges and bulk solids, including hygienic applications |
| Measuring Range : Liquids 10 m (33 ft) / solids 5 m (16 ft) | Brand : Endress+Hauser |

EH-FDU92
| Measuring Principle : Ultrasonic Time-of-Flight | Application : Non-contact level of liquids, pastes, sludges and bulk solids |
| Measuring Range : Liquids 20 m (65 ft) / solids 10 m (33 ft) | Brand : Endress+Hauser |

EH-FMU30
| Measuring Principle : Ultrasonic Time-of-Flight | Application : Level of liquids and bulk solids in sewage plants, process water, loading, storage and buffer tanks |
| Measuring Range : Liquids up to 8 m (26 ft) | Brand : Endress+Hauser |

EH-FMU40
| Measuring Principle : Ultrasonic Time-of-Flight | Application : Non-contact level of liquids, pastes and coarse bulk solids; open channel flow |
| Measuring Range : Liquids 5 m (16 ft) / solids 2 m (6.6 ft) | Brand : Endress+Hauser |

EH-FMU90
| Measuring Principle : Ultrasonic Time-of-Flight (transmitter / controller) | Application : Level and open channel flow measurement, pump control, 1 or 2 sensors |
| Measuring Range : Up to 45 m (148 ft) | Brand : Endress+Hauser |

EH-FMB70
| Measuring Principle : Hydrostatic Pressure | Application : Level of liquids and pastes in open or closed tanks; process and hygienic applications |
| Measuring Range : 100 mbar to 10 bar (1.5-150 psi) | Brand : Endress+Hauser |

EH-FTW33
| Measuring Principle : Conductive (combined with capacitive) | Application : Hygienic point level detection in pipes, storage tanks and process vessels |
| Process Connection : G½-G1, M24, Clamp ISO 2852 | Brand : Endress+Hauser |

EH-CLD18
| Measuring Principle : Inductive (Toroidal) Conductivity | Application : CIP process control and concentration monitoring in beverage plants |
| Measuring Range : 200 µS/cm to 1000 mS/cm | Brand : Endress+Hauser |

EH-CLS16E
| Measuring Principle : Conductive, coaxial electrodes | Application : Pure and ultrapure water in life sciences and food |
| Measuring Range : 0.04 to 500 µS/cm | Brand : Endress+Hauser |

EH-CLS21E
| Measuring Principle : Conductive, 2 graphite electrodes | Application : Potable, desalination and industrial water |
| Measuring Range : 10 µS/cm to 20 mS/cm | Brand : Endress+Hauser |

EH-CLS82E
| Measuring Principle : Conductive, 4-electrode | Application : Hygienic and pharma processes: fermentation, chromatography, final rinse |
| Measuring Range : 1 µS/cm to 500 mS/cm | Brand : Endress+Hauser |

EH-CLD134
| Measuring Principle : Inductive (Toroidal) Conductivity | Application : Hygienic and sterile processes in food, beverage and life sciences |
| Measuring Range : 100 µS/cm to 2000 mS/cm | Brand : Endress+Hauser |

EH-CM44X
| Measuring Principle : Digital communication via Memosens protocol | Application : Multi-parameter liquid analysis with one controller |
| Channels : Up to 8 channels | Brand : Endress+Hauser |

EH-CPS11E
| Measuring Principle : Potentiometric, gel compact electrode with PTFE ring junction | Application : Chemical, pulp and paper, power plants and water treatment |
| Measuring Range : pH 0 to 14 | Brand : Endress+Hauser |

EH-CPS61E
| Measuring Principle : Potentiometric, gel compact electrode with ceramic junction | Application : Bioreactors and CIP/SIP in food and beverage |
| Measuring Range : pH 0 to 14 | Brand : Endress+Hauser |

EH-CPS71E
| Measuring Principle : Potentiometric, gel compact electrode with ceramic junction and ion trap | Application : Chemical processes and electrode-poisoning media such as H₂S |
| Measuring Range : pH 0 to 14 | Brand : Endress+Hauser |

EH-CML18
| Measuring Principle : Memosens digital sensors (pH/ORP, conductivity, dissolved oxygen) | Application : Field and lab checks of measuring points, samples and process points |
| Dimensions : 84 x 54 x 47 mm (3.3 x 2.1 x 1.9 in) | Brand : Endress+Hauser |

EH-CPA871
| Type : Manual or pneumatic retractable assembly | Application : Holds 12 mm pH/redox sensors; sensor can be removed without stopping the process |
| Stroke : 36 mm and 78 mm (1.4 and 3.1 in) | Brand : Endress+Hauser |

EH-CPF81E
| Measuring Principle : Potentiometric, gel compact electrode with PTFE diaphragm | Application : Mining and industrial water and wastewater treatment |
| Measuring Range : pH 0 to 14 | Brand : Endress+Hauser |

EH-CYK10
| Operating Principle : Non-contact inductive coupling | Application : Connects Memosens sensors to transmitter (pH/ORP, DO, conductivity, disinfection) |
| Cable Length : Up to approx. 100 m (328 ft) | Brand : Endress+Hauser |

EH-CUS51D
| Measuring Principle : Four beam alternating light | Application : Water, wastewater and industrial utilities |
| Measuring Range : 0 to 4000 FNU | Brand : Endress+Hauser |

EH-CAS51D
| Measuring Principle : UV photometric | Application : Organic load and nitrate monitoring in water and wastewater |
| Measuring Range : Nitrate 0.01 to 50 mg/l NO₃-N | Brand : Endress+Hauser |

EH-CAS80E
| Measuring Principle : UV/VIS absorbance at 200 to 800 nm | Application : Drinking water, surface water, wastewater and utility water |
| Parameters : TOCeq, CODeq, BODeq, turbidity, nitrate, SAC254 | Brand : Endress+Hauser |

EH-TMT82
| Measuring Principle : Temperature transmitter for RTD, thermocouple, Ω and mV sensors | Application : Industrial processes requiring high availability and field installations in harsh environments |
| Channels : 2 channels (universal input) | Brand : Endress+Hauser |

EH-TM131
| Measuring Principle : RTD or thermocouple (TC) | Application : Power, chemical, oil and gas, water/wastewater and utilities |
| Temperature Range : Pt100 -50 to 500 °C, TC Type K up to 1,100 °C | Brand : Endress+Hauser |

EH-PMP43
| Measuring Principle : Absolute and gauge pressure with metal diaphragm sensor | Application : Pressure and hydrostatic level in hygienic process pipes, tanks and pressurized vessels |
| Measuring Range : 400 mbar to 100 bar (6 to 1,450 psi) | Brand : Endress+Hauser |

EH-PMP71B
| Measuring Principle : Absolute and gauge pressure with metallic process diaphragm | Application : Industrial process pressure with device health verification during operation |
| Measuring Range : 400 mbar to 700 bar (6 to 10,150 psi) | Brand : Endress+Hauser |

EH-PMP21
| Measuring Principle : Piezoresistive sensor with metallic measuring diaphragm | Application : Utilities, pump systems, machines and process vessels |
| Measuring Range : 400 mbar to 400 bar (6 to 5,800 psi) | Brand : Endress+Hauser |

EH-PMP23
| Measuring Principle : Piezoresistive sensor with metallic measuring diaphragm | Application : Hygienic applications in food and beverage |
| Measuring Range : 400 mbar to 40 bar (6 to 580 psi) | Brand : Endress+Hauser |

EH-PMP51B
| Measuring Principle : Absolute and gauge pressure with welded metal diaphragm | Application : Process pressure and level in liquids and gases |
| Measuring Range : 400 mbar to 400 bar (6 to 5,800 psi) | Brand : Endress+Hauser |

EH-PTP31B
| Measuring Principle : Piezoresistive sensor | Application : Absolute and gauge pressure monitoring in OEM skids and process systems |
| Measuring Range : 400 mbar to 400 bar (6 to 5,800 psi) | Brand : Endress+Hauser |

EH-PTP33B
| Measuring Principle : Metal diaphragm | Application : Pressure monitoring in hygienic and general process applications |
| Measuring Range : 400 mbar to 40 bar (6 to 580 psi) | Brand : Endress+Hauser |

EH-PMC51B
| Measuring Principle : Absolute and gauge pressure with ceramic process membrane | Application : Highly accurate measurement of liquids and gases, vacuum resistant |
| Measuring Range : 100 mbar to 40 bar (1.5 to 580 psi) | Brand : Endress+Hauser |

EH-PMC71B
| Measuring Principle : Absolute and gauge pressure with ceramic (Ceraphire) membrane | Application : Process pressure and level in liquids or gases, with anomaly detection |
| Measuring Range : 100 mbar to 40 bar (1.5 to 580 psi) | Brand : Endress+Hauser |

EH-PMC51
| Measuring Principle : Capacitive cell with ceramic (Ceraphire) process membrane | Application : Pressure in gases, steam and liquids, plus level and volume |
| Measuring Range : 100 mbar to 40 bar (1.5 to 580 psi) | Brand : Endress+Hauser |

EH-PMC71
| Measuring Principle : Capacitive, oil-free ceramic measuring cell | Application : Pressure, level, volume or mass measurement of liquids and gases in process and hygienic applications |
| Measuring Range : 100 mbar to 40 bar (1.5 to 580 psi) | Brand : Endress+Hauser |

EH-RSG45
| Function : Secure data recording, signal analysis and visualization | Application : Organizing process values in chemical, water/wastewater, food & beverage, power & energy, mining, oil & gas, pulp & paper and life science industries |
| Inputs : Up to 20 analog, up to 20 HART, up to 14 digital | Brand : Endress+Hauser |

EH-RSG35
| Function : Secure recording, display and monitoring of analog/digital signals with web-based remote configuration | Application : Water monitoring, industrial process water, raw materials processing and control cabinets |
| Inputs : Up to 12 analog, up to 6 digital | Brand : Endress+Hauser |

EH-FMA90
| Function : Control unit for radar, ultrasonic, hydrostatic or universal 4-20 mA / HART level sensors | Application : Open channel flow, water level and temperature monitoring, pump control and bulk solids storage monitoring |
| Inputs : 1 or 2 × 4-20 mA / HART | Brand : Endress+Hauser |

EH-RIA15
| Function : Process value display, powered directly from the 4-20 mA loop with no external supply | Application : Process monitoring in chemical, water/wastewater, food & beverage, power, mining, oil & gas and pulp & paper industries |
| Inputs : 1 × analog 4-20 mA / HART | Brand : Endress+Hauser |

PMD75B
| Measuring Principle : Differential pressure, metal membrane, Bluetooth wireless, Heartbeat diagnostics | Application : Pressure differences in liquids and gases, with plugged impulse line detection |
| Size Range : 10 mbar...250 bar (0.15...3750 psi) | Brand : Endress+Hauser |

PMD75
| Measuring Principle : Differential pressure, piezoresistive metal sensor | Application : Liquids, vapors and gases; level, volume, mass and flow with primary elements |
| Size Range : 10 mbar...250 bar (0.15...3750 psi) | Brand : Endress+Hauser |

PMD55B
| Measuring Principle : Differential pressure, metal membrane, Bluetooth wireless | Application : Pressure differences in liquids and gases, with app-based remote operation |
| Size Range : 10 mbar...40 bar (0.15...600 psi) | Brand : Endress+Hauser |

PMD55
| Measuring Principle : Differential pressure, piezoresistive metal sensor | Application : Pressure differences in liquids, vapors and gases; filter and pump monitoring |
| Size Range : 10 mbar...40 bar (0.15...580 psi) | Brand : Endress+Hauser |

FMR30B
| Measuring Principle : 80 GHz Radar (non-contact, free space) | Application : Liquids and solids in water, wastewater, open channels, silos and tanks |
| Size Range : 20 m (40 mm / 1-1/2") or 30 m (80 mm / 3") | Brand : Endress+Hauser |

FMR67B
| Measuring Principle : 80 GHz Radar (non-contact) | Application : Continuous level measurement of demanding solids, including extreme temperatures |
| Size Range : Up to 125 m (410 ft) | Brand : Endress+Hauser |

EH-PMD63B
| Measuring Principle : Differential pressure | Application : Hydrostatic level and differential pressure of liquids and gases, including filter monitoring |
| Measuring Range : 100 mbar to 40 bar (1.5 to 580 psi) | Brand : Endress+Hauser |

EH-PMP63B
| Measuring Principle : Piezoresistive sensor with diaphragm seal | Application : Absolute pressure, gauge pressure and hydrostatic level of liquids and gases in Food & Beverage and Life Sciences |
| Measuring Range : 100 mbar to 100 bar (1.5 to 1,450 psi) | Brand : Endress+Hauser |

CYA27
| Type : Modular flow assembly for simultaneous multi-parameter measurement | Application : Drinking, process, cooling, sea and pool water |
| Sample Flow : As low as 5 l/h (1.32 gph) | Brand : Endress+Hauser |

CYK11
| Operating Principle : Waterproof digital signal transmission, no contact corrosion | Application : Extends Memosens measuring points in water and process applications |
| Cable Length : Up to 85 m (279 ft) | Brand : Endress+Hauser |

CPM223
| Measuring Principle : Potentiometric (pH and ORP/redox) | Application : Chemicals, food and beverage, power, water treatment and primary metals (non-hazardous areas) |
| Dimensions : 96 x 96 x 146 mm (3.8 x 3.8 x 5.7 in) | Brand : Endress+Hauser |